Wissensdatenbank
Wissensdatenbank

der Nutzer muss sich in kurzen Abständen am Wlan (Gast) erneut authentifizieren (vSZ)

Session Timeout and Grace Period: https://support.ruckuswireless.com/answers/000005878

Check the "Advanced Options" section of the wlan with WebAuth and set the "Grace period". By default it's 30 minutes. The 30 minute is from the time the client was last seen, not from when it first connects.

ZD: https://support.ruckuswireless.com/answers/000003241

Sind Produkte von Aerohive von der Schwachstelle "Logjam" betroffen?

Nein.

Antwort von Aerohive: "No, Aerohive products running recent versions of our code are not susceptible to the LOGJAM attack."

Nach update des BR200 von 6.2 auf 6.4 können Lan-gebundene Devices nicht mehr ins Internet/Netz.

 

Hintergrund:

die ETH0-Schnittstelle muss nach dem update manuell gestartet werden.

Bitte testen Sie ob sich das Interface, wie untenstehend beschrieben nach dem update, am BR200 wieder in Betrieb nehmen lässt.

Der Hersteller empfiehlt jedoch für dieses Gerät bei der Version 6.2 zu bleiben.


"
Unfortunately, we do have an issue with the WAN interface on BRs running 6.4 that require the Eth0 port to be restarted manually after a configuration upload or reboot.
You can run 'int eth0 shut' and then 'no int eth0 shut' to restart that interface
but I do recommend reverting back to 6.2 until we release 6.6r1 which should fix this issue.

"

Die HivemanagerVA ist nur als VMWare-OVA-Image verfügbar.

die HivemanagerVA ist nicht als Hyper-V-Image verfügbar.
Sie können die VMWare-OVA zu Hyper-V konvertieren.

Barracuda NG Firewall version 5.2.5 tainted

Due to several severe issues that our support team has encountered with the recently released Barracuda NG Firewall version 5.2.5, we have decided to remove all 5.2.5 packages from the download area. As of now please refrain from upgrading your firewalls or control centers to version 5.2.5. If you have already done so, we recommend a downgrade to the previously installed version.
We are working hard to resolve the various issues. I would like to apologize on behalf of the entire Barracuda NG Firewall team for any inconvenience this has caused our customers and partners. I hope you bear with us while we get this fixed. If you have any further questions please contact our support team.

Klaus M. Gheri
Vice President, Product Management Europe
Barracuda Networks


Jesus Cordero-Guzman
Premium Support Manager EMEA
Barracuda Networks Support Team

Barracuda Networks AG
Eduard-Bodem-Gasse 1
6020 Innsbruck
Austria

Phone: +43 (0)508 100-800
Fax: +43 (0)508 100-20
eMail: EmeaSupport@barracuda.com<mailto:EmeaSupport@barracuda.com>
Web: www.barracudanetworks.com<http://www.barracudanetworks.com/>

 

Bitte löschen Sie die vorhandenen CWP-Files aus den APs und führen ein update der Konfiguration durch.
mit dem Command-Befehl "clear web-directory",

oder die GUI > " Update > Advanced > Remove Captive Web Portal Settings" können Sie die evtl. korrupten Files auf dem AP löschen.

Reboot > Konfiguration neu laden.

Der Entitlement-Key zeigt keine Devices (permanent renew).

 

In der HiveManager-Übersicht "Home > Administration > License Management > Entitlement Key Information" werden bei den "permanent renew" Entitlement-Keys keine Devices gelistet.

Dies ist korrekt, die Devices sind über den Orginal-Key lizensiert.

""After applying the key, it will show 0 devices licensed;
this is normal since the customer is still licensed with the original key,""

 

Eine Übersicht der lizensierten Devices finden Sie unter "home > Administration > License Management > HiveManager License Information" .

 

Barracuda Product Notice

To: Distributors and Resellers of Barracuda Networks’ Products

From: Russell Johnson, Barracuda Networks, Inc.

Date: 12/4/12


Barracuda Networks, Inc. (“Barracuda”) is committed to conducting its business with honesty, integrity, and in full compliance with U.S. and foreign export control and trade and economic sanctions regulations. Compliance with these laws is critical to Barracuda's reputation and success.

As a reseller or distributor of Barracuda products, you have an affirmative obligation to comply with U.S. export regulations for all products you resell to customers worldwide. Therefore, new product sales, renewals, upgrades or services may not be sold, shipped, delivered or otherwise transferred to any destination that is subject to U.S. government regulations as follows:

* Embargoed countries: Cuba, Iran, North Korea, Sudan, and Syria. Products may not be sold to or used in these countries.

* Denied Parties (Full list available to Barracuda partners per details below): Products may not be sold or used by parties on this list at any time. As this list is subject to change without notice, all new and renewal partners shall be checked against this list prior to submitting an order to Barracuda.

http://content.barracudanetworks.com/e/10742/login-cfm/xssrv/314382405 <http://content.barracudanetworks.com/e/10742/login-cfm/xssrv/314382405>
user ID: public
password: public.

* Prohibited uses: When permissible, items destined for nuclear, chemical, or biological weapons proliferation will require a U.S. or other government license or permit. Licenses can take as much as 60 days to obtain and there is no guarantee a license will be granted.

* Technology Restrictions: Barracuda encrypted products classified as 5D002, 740.17(b)(2) will require licenses for government and military end users not located in Supplement 3 countries: (Australia, Austria, Belgium, Bulgaria, Canada, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Japan, Latvia, Lithuania, Luxembourg, Malta, Netherlands, New Zealand, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey, United Kingdom). For a list of the classifications of our current products, visit our website: http://content.barracudanetworks.com/e/10742/tradecompliance/xssqv/314382405.

Barracuda expects your strict compliance at all times with these regulations and requirements. Partners who violate this requirement will be subject to immediate termination.

Links to the relevant U.S. Government agencies and laws are located at: http://content.barracudanetworks.com/e/10742/index-htm/xssr6/314382405 and http://content.barracudanetworks.com/e/10742/of-Foreign-Assets-Control-aspx/xssrj/314382405<http://content.barracudanetworks.com/e/10742/index-htm/xssr6/314382405%20and%20http://content.barracudanetworks.com/e/10742/of-Foreign-Assets-Control-aspx/xssrj/314382405>. The key US regulations applicable to export are:

* The Export Administration Regulations, administered by the Bureau of Industry and Security, apply to the sale, shipment and transfer of our goods and technology to foreign companies and foreign persons located both in the United States, and abroad.

* The trade and economic sanctions regulations, administered by the Office of Foreign Assets Controls, restrict trade, investment, and financial transactions with certain countries, organizations, and individuals.

Should you have any questions, please contact Barracuda TradeCompliance_Team@barracuda.com

<redir.aspx?C=w_8r1pB_kUetLMtNbJQPC5rPn78Ups9I-bQjuV2NUWyD5UbpuQzMp0XL6OsC8sPgocneaREsv80.&URL=mailto%3aTradeCompliance_Team%40barracuda.com>We value your participation as a Barracuda partner, and look forward to our mutual continued success.


Sincerely,

Russell Johnson
Sr. Vice President of Operations

um das Betriebsystem "LisconOS" am ThinClient zurücksetzen folgen Sie folgender Anleitung:

https://www.stratodesk.com/kb/de/Zur%C3%BCcksetzen_in_den_Auslieferungszustand

(Start > Konfiguration > an der Verwaltungskonsole als Admin anmelden > im Menü "Werkseinstellungen" > mit klick auf den Knopf (grüner Haken) bestätigen)

Ports has to be opened on the firewall when Ruckus ZDs and APs are separated by Layer3 network.

 

(FireWall ports need to be open in front of the ZD)

TCP 443 - TR-069 & Web UI (config sync between ZDs when using Smart Redundancy)

TCP 33003 - Smart Redundancy

TCP 80 - if initial request to ZD WebGUI is via http

UDP 12222 - LWAPP data messages

UDP 12223 - LWAPP control messages

TCP 21 - AP upgrade (AP initiates port 21 PASV FTP connection - FW must be PASV FTP stateful)

UDP 18301 - SpeedFlex

Die R3xx-APs von Ruckus sind die "entry-level indoor Access Point ".

Als Einsteiger Modelle unterstützen keine SmartMesh. Weder in der "managed" noch in der "unleased" Version.

Dieses Feature kann weder nachgerüstet werden noch ist die Implimentierung geplant.

SmartMesh-fähige APs beginnen mit dem R500.

*****************************************************************************

Ich würde Ihnen wirklich gerne eine klare Stellungnahme bezüglich der
Microsoft Lizenzen geben.
Einer unserer Kunden (Teil der deutschen Regierung) hat Microsoft um
eine solche Stellungnahme (in unserem Interesse) gebeten.

Wir baten um Klärung, da auf der einen Seite der Remote-Zugriff erlaubt
ist, wenn auf beiden Seiten Lizenzen für das installierte Microsoft
Betriebssystem vorliegen, auf der anderen Seite aber wieder nicht
erlaubt wird. Aus unserer Sicht (und der unserer Kunden) ist dies nicht
klar definiert und widerspricht sich (gilt nur für Windows 7).
Leider warten wir noch immer auf eine derartige Stellungnahme und ich
kann Ihnen die Frage nicht beantworten, wann und ob wir überhaupt eine
solche bekommen. Es scheint hier einen "Grau-Bereich" zu geben ....

Einer unserer Kunden hat uns die Stellungnahme einer unserer Mitbewerber
weitergeleitet.
Diese argumentieren folgendermaßen:

**********************************************************************
Hello,

Yes, this is an easy question and frequently asked question.
W7 64 bits (Pro is recommended) is a perfect system and do a better
job than W2008.
W7 includes 15 client CALS and our built-in web server has no user limit

The US Army, U.C.L.A., the Ministry of Justice in France, the Police
of New-York and Paris, hundreds of law firms and chartered accounts
are using TSplus and your question.

If your concerns are about Microsoft Eula, this extract from Windows
Seven Eula will clear things out:

g. Remote Access Technologies. You may access and use the software
installed on the licensed computer remotely from another device
using remote access technologies as follows.
• Remote Desktop. The single primary user of the licensed computer
may access a session from any other device using Remote Desktop or
similar technologies. A “session” means the experience of
interacting with the software, directly or indirectly, through any
combination of input, output and display peripherals. Other users
may access a session from any device using these technologies, if
the remote device is separately licensed to run the software.
• Other Access Technologies. You may use Remote Assistance or
similar technologies to share an active session.

This means that you can open a session from any Windows pc because
"this remote device is separately licensed to run the software".

Kind regards,

John Davies

**********************************************************************




Auf der anderen Seite sind weder Thinstuff noch Microsoft in der der
Lage zu sagen, ob ein Software Produkt legal ist oder nicht. Diese
Entscheidung kann und muss alleine von der Judikatur es jeweiligen
Landes getroffen werden.

Unabhängig davon tragen aber grundsätzlich immer die Endbenutzer
(Einzelpersonen bzw. Firmen) die Verantwortung dafür, dass die
Bestimmungen, Einschränkungen und Hinweise der Microsoft Windows
Endbenutzer-Lizenzverträge erfüllt werden.

Bei bestehenden Unklarheiten und Zweifeln sollten sich Endbenutzer zur
Klärung mit Fragen bezüglich der Windows-Lizenzierung und den Windows
Endbenutzer-Lizenzverträgen direkt an ihren Microsoft-Vertreter oder
-Reseller wenden.



Falls Sie noch weitere Fragen haben, können Sie sich gerne jederzeit an
uns wenden.

Mit freundlichen Grüßen
Mona Lippert-Winkel

Thinstuff s.r.o.
Bajkalská 5/C
831 04 Bratislava, Slovakia

support@thinstuff.com

Thinstuff und Scanner Plustek - scan schlägt fehl.

Grund: der Plustek-Treiber aus dem Internet mit der Version 5.2.0 verursacht einen Datasource Fehler .
Dieser Treiber muss deinstalliert werden.

Installieren Sie den Original-Treiber von der CD (5.1.0).

Beliebteste Artikel 
 
Neuester Artikel 
 
Impressum sysob IT-Unternehmensgruppe GmbH & Co. KG